o you still gain your water for industrial and domestic use through desalinization and reverse osmosis from your drinking water supply?
N
ature already provides us lime-free, salt-free water through the rain.
How can we use this natural resource?
R
ainwater is collected on the roofage. Solids and suspended particles are removed through cross flow microfiltration. The pH value is adjusted by the carefully measured addition of soda lye. The sterilized deactivated water can be used to refill cooling-water circuits, as water for component-washers, and as lavatory flush.
Chemical requirement:
1% compared with the chemical-physical process of filter-purification.
Water conditioning:
10 -20% of the costs compared with the chemical-physical process
Cost amortization:
6-12 months, according to our experience
The first component washer for gas-/plasmanitriding parts, on the basis of rainwater operates to the fullest satisfaction of the operators.
Home
Our services
About us
Cooperation with our partners
Reichert Consulting GmbH Geschäftsführer Paul Reichert
Am Bruckerfeld 4 D-82547 Beuerberg
Telefon: 0049 - 81 79 - 58 07 Telefax: 0049 - 81 79 - 92 59 96 Email Reichert@reichert-consulting.com